Temperature controller, used for field with automatic switch between heating and cooling
Click image to view full size image
Product: Views:163Temperature controller, used for field with automatic switch between heating and cooling 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-12-18 01:01
  Inquiry
Details
Model Number: 418-A01 RC-310M Key Specifications/Special Features: Main functions and features:Product adopts the latest electronic technique with LED display, which learnfrom the advantages and experience of stand-alone edition temperaturecontrollers domestically and overseasMost economical product withsimple operation, stable performance, small size and intelligent control, cool andheat shiftfunctions, which applies to various refrigeration and heating places andequipmentsUser menu and administrator menu can be set separatelyNot only convenientfor user operation, but also left enough space for the adjustment of high-levelmanagementMain technical parameters:
  • Temperature measure range: - 40 to 230°F
  • Resolution: 0.1°F (≤199. 9), 1°F (>200°F)
  • Accuracy: ±2°F
  • Power supply: 110V AC ±10%, 50/60Hz
  • Input: one NTC sensor
  • Output: relay 10A/250V AC
  • Ambient requirements:
    • Temperature: -10 to 60°C
    • Humidity: 20-85% (no condensate)
  • Cut-out size: 71x29mm
  • Consumption: ≤3W
  • Function description:
    • Temperature calibration
    • When there is difference between the measuring temperature and the standard temperature, this function can keep the measuring temperature same as the standard temperature
    • Temperature after calibration
    • Temperature before calibration + adjusted value
  • Cool and heat function:
    • When the measuring temperature ≥ set temperature + cool differential, cooling relaypick-up, and cool outputs
    • When the measuring temperature < set temperature, coolingrelay opens, and cool stop outputting
    • When the measuring temperature ≤ settemperature the heat differential heating relay pick-up, heat outputs
    • When the measuringtemperature > set temperature, heating relay opens, and heat stop outputting
  • Compressor delay:
    • When power on for the first time, if the measuring temperature≥ set temperature + temperature differential, compressor output will not be activated immediately, and will beactivated after the delay time
    • If time period between the compressor previous stop and this starts is longer thanthe delay time, the cool output will be activated immediately, if it is shorter than the delaytime, the output will be activated after the delay time
    • Delay time is calculated fromthe previous cool output stop
  • Shipping Information:
    • FOB Port: Shanghai
    • Lead Time: 20 - 45 days
    Main Export Markets:
    • Central/South America
    • Eastern Europe
    • North America
    • Mid East/Africa
    • Asia
    • Western Europe
    • Australasia
    Inquiry